Charging R-410A Refrigerant Into An Air Conditioner Using Wireless Probes!
In this HVAC Training Video, I Show How to Use Wireless Probes to Check the Refrigerant Charge and How to Correctly Charge R-410A Refrigerant into this Running Air Conditioner! Technicians Must be EPA 608 Certified to Handle Regulated Refrigerants! Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety.
Tools Used In The Video:
Fieldpiece Complete Job Link Probe Kit - trutechtools.com/Fieldpiece-Complete-Job-Link-Probe-Kit-TTT-Exclusive?aff=8
Fieldpiece STA2 Thermal Anemometer Hotwire AirFlow Meter trutechtools.com/STA2?aff=8
Hilmor RSWL220 Wireless Refrigerant Scale 220lbs trutechtools.com/hilmor-rswl220-wireless-refrigerant-scale-220lbs.html?aff=8
At Trutechtools.com use code acservicetech for 8% off
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our Related Videos:
ua-cam.com/video/-pN9EoUZX8c/v-deo.html
ua-cam.com/video/9l3n7yQ_N5k/v-deo.html
ua-cam.com/video/obZgCt5d8bg/v-deo.html
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
All Our Educational Products on Our Site: www.acservicetech.com/store
All Our Educational Products on Amazon: amzn.to/48pDd82
Mini Split Book and E-Book on Our Site- www.acservicetech.com/mini-split-book
Mini Split Paperback on Amazon- amzn.to/3ytHJSs
Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGuides?aff=8
Refrigerant Charging Book and E-Book: www.acservicetech.com/ac-book
Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Online Resources!
Our HVAC Calculators: www.acservicetech.com/hvac-calculators
Our Newest Articles: www.acservicetech.com/articles
Try our HVAC/R Quizzes! www.acservicetech.com/quizzes
Our Other Resources: www.acservicetech.com/resources
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Tools Used in Our Videos!
Tool Links on Our Site: www.acservicetech.com/tools
Our Tool List on Amazon: www.amazon.com/shop/acservicetech
Support the Channel by purchasing tools through Tru Tech Tools!
Use this link www.trutechtools.com/?aff=8
Save 8% at checkout using code "acservicetech"
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Follow Us On Our Social Media & Podcasting Channels!
Patreon: www.patreon.com/acservicetech
Facebook: acservicetech
Instagram: acservicetech
X: acservicetech
LinkedIn: www.linkedin.com/company/ac-service-tech-llc
Tiktok: www.tiktok.com/@acservicetech
Spotify: open.spotify.com/show/74KXLz5uJoQZXG8V5F2r9n
Apple Podcasts: podcasts.apple.com/us/podcast/ac-service-tech-answers-podcast/id1522359430
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
⚠️ Disclaimer:
Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided.
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
#hvacr #hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #hvactechs #technician #training #airconditioner #airconditioning #r410a #charge #checkingthecharge #refrigerant #refrigerantcharging
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Shop through Amazon! Your purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.
Переглядів: 13 895

Відео

R-32 and R-454B Checking the Refrigerant Charge Scenarios! Practice for HVAC Techs!
Переглядів 18 тис.14 днів тому
In This HVAC Training Video, I Show 4 Refrigerant Charge Scenarios, Two For R-32 & Two For R-454B. Technicians Have Been Asking Questions On How These New Refrigerants Will Differ In Their Charging & Checking The Charge Methods Compared to R-22 & R-410A, If At All. Supervision is Needed by a Licensed HVACR Tech While Performing Tasks as Experience and Apprenticeship Garners Wisdom and Safety. T...
Air Conditioning Basics Class! Airflow CFM, Sensible & Latent Heat, Dew Point, Condensate, Delta T!
Переглядів 16 тис.Місяць тому
In this HVAC Training Video, Ty Branaman From @love2hvac Discusses How Refrigerant Pressure and Saturated Temperature Changes Due to Adjustments in the Airflow! He also Discusses Sensible and Latent Temp, Dew Point, Humidity Removal, Condensation, Delta T and More! Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety. T...
Single Stage SCROLL Refrigerant Compressor Operation and Internal Parts Explained!
Переглядів 7 тис.Місяць тому
In this HVAC Training Video, I show all the Internal Parts of a Single Stage Scroll Refrigerant Compressor using the Copeland Training Kit! This is the same refrigerant compressor used in most air conditioning and heat pump units containing R-410A! Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety. ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬...
A2L Refrigerants R-454B and R-32 Explained! Bottles, Changes, Rules, Tools!
Переглядів 87 тис.Місяць тому
In this HVAC Training Video, I Explain the Changes to the New A2L Refrigerants R-454B and R-32! I Explain Why This is Happening in Air Conditioners and Heat Pumps! We Cover How the Bottles Differ, What the Pressures Look Like, the Additional Safety Sensors Required, Tool Updates, and How Procedures are Affected! Supervision is needed by a licensed HVACR Tech while performing tasks as Experience...
Troubleshooting With Sat Temps, Superheat, & Subcooling! 5 Possible Problems!!
Переглядів 55 тис.Місяць тому
In this HVAC Training Video, Learn to Troubleshoot Why the Pressure and Saturated Temperature are so Low on the Vapor/Suction Line of a Running Air Conditioning System. With these 5 Scenarios, You can Test Your knowledge and Learn About Why the Indoor Coil and Tubing may be Frosting and Freezing, in Order to Fix the Unit. Supervision is needed by a licensed HVACR Tech while performing tasks as ...
Basics of Refrigerant Class! Bottles, Saturation, P/T Chart, Pressures, Temperatures
Переглядів 23 тис.2 місяці тому
In this HVAC Training Video, I Show the Basics of Refrigerants, Refrigerant Bottles, the Correlation Between Pressures and Temperatures, Using a P/T Chart, and Determining What Refrigerant is in a Used Recovery Bottle. Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety. Tools Used In The Video Our Quick Reference Card...
Copper Line Set Tube Corrosion and HVAC Refrigerant Leaks Explained!
Переглядів 21 тис.2 місяці тому
Copper Line Set Tube Corrosion and HVAC Refrigerant Leaks Explained!
LEV/EEV Electric Expansion Valve Operation and Troubleshooting! HVAC Metering Devices!
Переглядів 19 тис.2 місяці тому
LEV/EEV Electric Expansion Valve Operation and Troubleshooting! HVAC Metering Devices!
Multi-Zone Mini Split, Mini-VRF, and VRF System Differences Explained!
Переглядів 10 тис.3 місяці тому
Multi-Zone Mini Split, Mini-VRF, and VRF System Differences Explained!
Automatic Air Vent Operation and Servicing on Hydronic Heat Boiler Systems!
Переглядів 9 тис.3 місяці тому
Automatic Air Vent Operation and Servicing on Hydronic Heat Boiler Systems!
ECM Fan Motor Won't Turn On or Won't Shut Off on HVAC Unit! Testing the Board and Fan Motor!
Переглядів 50 тис.3 місяці тому
ECM Fan Motor Won't Turn On or Won't Shut Off on HVAC Unit! Testing the Board and Fan Motor!
Gas Valve Types and Operation on GAS FURNACES!
Переглядів 11 тис.4 місяці тому
Gas Valve Types and Operation on GAS FURNACES!
How to Remove a Mini Split Fan Wheel!
Переглядів 34 тис.4 місяці тому
How to Remove a Mini Split Fan Wheel!
Gas Furnace Training- Intermittent Pilot Ignition: Gas Valve, Spark, Module, Operation, Testing!
Переглядів 29 тис.5 місяців тому
Gas Furnace Training- Intermittent Pilot Ignition: Gas Valve, Spark, Module, Operation, Testing!
Honeywell Smart Valve Operation, Testing, Wiring! HVAC Gas Furnace Training!
Переглядів 27 тис.5 місяців тому
Honeywell Smart Valve Operation, Testing, Wiring! HVAC Gas Furnace Training!
Most Common and Basic Problem on High Efficiency Furnaces!
Переглядів 35 тис.6 місяців тому
Most Common and Basic Problem on High Efficiency Furnaces!
Gas Furnace Burner Training!
Переглядів 18 тис.6 місяців тому
Gas Furnace Burner Training!
Gas Furnace Direct Ignition GAS VALVE OPERATION! Pressures, Voltage, Tools, LP Propane, Natural Gas
Переглядів 15 тис.6 місяців тому
Gas Furnace Direct Ignition GAS VALVE OPERATION! Pressures, Voltage, Tools, LP Propane, Natural Gas
Gas Furnace Training & Testing: LED Status Error Codes for Carrier, Bryant, Payne
Переглядів 46 тис.7 місяців тому
Gas Furnace Training & Testing: LED Status Error Codes for Carrier, Bryant, Payne
Showing TXV Operation with a Water Stream! Thermostatic Expansion Valve Explained!
Переглядів 87 тис.7 місяців тому
Showing TXV Operation with a Water Stream! Thermostatic Expansion Valve Explained!
HVAC Low Airflow Diagnosis! 5 Methods to Determine if an AC Coil is Clogged with Dust!
Переглядів 26 тис.8 місяців тому
HVAC Low Airflow Diagnosis! 5 Methods to Determine if an AC Coil is Clogged with Dust!
Replacing an Indoor Mini Split Fan Motor on Fujitsu, Mitsubishi, and Daikin Wall Mounted Units!
Переглядів 32 тис.8 місяців тому
Replacing an Indoor Mini Split Fan Motor on Fujitsu, Mitsubishi, and Daikin Wall Mounted Units!
Circuit Boards, ECM Fan Motors, Thermostats, and More! HVAC Q&A - AC Service Tech Answers Podcast!
Переглядів 10 тис.9 місяців тому
Circuit Boards, ECM Fan Motors, Thermostats, and More! HVAC Q&A - AC Service Tech Answers Podcast!
HVAC CONTACTOR Operation, Types, Ratings, Problems, Testing!
Переглядів 71 тис.9 місяців тому
HVAC CONTACTOR Operation, Types, Ratings, Problems, Testing!
Operating Pressures, Subcooling, & Vacuum Problems! HVAC Q&A - AC Service Tech Answers Podcast!
Переглядів 12 тис.9 місяців тому
Operating Pressures, Subcooling, & Vacuum Problems! HVAC Q&A - AC Service Tech Answers Podcast!
Inverter Mini Split Heat Pump WORKBOOK!
Переглядів 6 тис.9 місяців тому
Inverter Mini Split Heat Pump WORKBOOK!
Gas Furnace Combustion Analysis Training with Tyler Nelson!
Переглядів 23 тис.9 місяців тому
Gas Furnace Combustion Analysis Training with Tyler Nelson!
7 Technical HVAC Questions Answered by Craig Mig and Ty Branaman! "AC Service Tech Answers Podcast!"
Переглядів 19 тис.9 місяців тому
7 Technical HVAC Questions Answered by Craig Mig and Ty Branaman! "AC Service Tech Answers Podcast!"
HVAC Metering Device Types: EEV, TXV, TEV, Piston, Capillary Tubing! Function, Location, Problems!
Переглядів 52 тис.10 місяців тому
HVAC Metering Device Types: EEV, TXV, TEV, Piston, Capillary Tubing! Function, Location, Problems!

КОМЕНТАРІ

  • @realestateinfonet9041
    @realestateinfonet9041 День тому

    Superb info! Thanks!

  • @user-ej4on2zt9s
    @user-ej4on2zt9s День тому

    Instead of a cup of ice in the attic and then running out side to see the gages can you just unhook the condensers fan? Then watch the gages from a chair?

  • @CreativeMaintenanceSolutions

    Ive got an R22 system that has 55 degree air coming out of the vents. Low side pressure of 70psig high side pressure of 170psig. I feel like the high side is too low. 85 degree day outside.

  • @povoljan13
    @povoljan13 День тому

    The charging hose has air when you hooked it up to the tee. The small space after the shutoff valve is dead air space. Needs a better setup maybe?

  • @realestateinfonet9041
    @realestateinfonet9041 День тому

    Superb info! Thank you very much!

  • @apeel2008
    @apeel2008 День тому

    Just found your channel. I have been having HVAC/Furnace issues with my drain line so have been looking at UA-cam to better understand what I don’t know. I have seen a lot of videos on drain lines, p-traps, air exchangers and exchange coils and this is THE BEST of all that I have seen. Your explain the different requirements for air handlers HVAC), exchange coils (Furnace) , and mini split systems. FANTASTIC. Thank you!

  • @robertleewhitt6241
    @robertleewhitt6241 День тому

    A half a gallon of Clorox bleach well completely clean out your line .

  • @mauroaparicio1855
    @mauroaparicio1855 День тому

    good

  • @jeremyroeder
    @jeremyroeder День тому

    I know the video is old, but I’m troubleshooting the blower motor on my unit now. I need to do the checks you discussed in this video. I did the hand test and cannot spin the shaft freely. It is hard to turn. When I took the shaft out, the bearings seem to spin freely but the permanent magnet rotor spins rough when it is inserted. I noticed a lot of black residue in the house in where the magnet rotor spins. I wonder if I should replace the bearings and clean the housing from debris?

  • @wuitdew36
    @wuitdew36 День тому

    You have a 20 amp breaker inside but what about the disconnect outside?

  • @jimwhite9483
    @jimwhite9483 День тому

    How hard would it be for Fieldpiece to add a wireless input for ODDB in the app or on the SMAN 380V?

  • @scoobtoober2975
    @scoobtoober2975 День тому

    This is the best explanation you have ever seen, heard or know if. Thank you. I'm starting out as a diy, considering a trade if needed. Very helpful. To diagnose anything you have to know the basics.

  • @fakenphonenews4252
    @fakenphonenews4252 День тому

    Coolest name ever

  • @peterman8058
    @peterman8058 2 дні тому

    Amrad's are a solid choice

  • @copkhan007
    @copkhan007 2 дні тому

    While the system was running, my guages were reading equal pressures on both high and low sides. I checked the capacitor, and it was good. Disconnected all three wires to the compressor, I was reading 1.3 ohms between the 2 terminals and OL between the other 2 terminals. My guess compressor is bad.

  • @Hsukhaybir
    @Hsukhaybir 2 дні тому

    Is the refrigerant has to be upside down like that ? I had an issue with my split’s inside unit it build up frost after an hour of turning the ac .. when the technician came “ which I’m not sure he’s totally a professional because he was the only one available “ he checked and says it need refill and refill it but the the tank was in normal positions not like this position and the AC was running while doing that.. should I do something about ti ?

  • @jordanb1759
    @jordanb1759 2 дні тому

    watched a lot of these videos. just charge to 38 degrees on the pink scale for R-410a. that's what it almost always comes out to

  • @johnharrisonschulz
    @johnharrisonschulz 2 дні тому

    This is a pretty good video. I was explaining this to my customer. After I left my customer, I decided to look up a video and this is exactly how I explained it to him.

  • @HVAC_Tips_Tricks_Calcs
    @HVAC_Tips_Tricks_Calcs 2 дні тому

    Although I’m sure sponsored, nice to see someone make a video that didn’t say you had to use MQ and True Flow or you’re a hack.

  • @bobward7489
    @bobward7489 2 дні тому

    "GWP" is absolutely MEANINGLESS as long as China and India are allowed to spew whatever they choose into the air and the water. We, the US, are already the cleanest industrialized nation. Someone tell me why we should be burdened so heavily

  • @paulrmfd
    @paulrmfd 2 дні тому

    absolutely instructional keep up the good work

  • @francinecorry633
    @francinecorry633 2 дні тому

    What is mfd?

  • @jharrison6557
    @jharrison6557 2 дні тому

    Does this work with automotive AC, using r134a or YF1234?

  • @ErsinGokay
    @ErsinGokay 2 дні тому

    Thank you for sharing the information with the interested audience. This is very detailed and informative video on the mini splits. Thank you once again for taking the time to create and share this video. God bless you.

  • @ScaryGoodConvo
    @ScaryGoodConvo 2 дні тому

    I had one fail the other day on my upstairs AC obviously due to the heat. It's been consistently upper 90s the past few weeks in GA.

  • @drdickqueso
    @drdickqueso 2 дні тому

    Superheat takes place in the top of the units and compressor. Sub cooling takes place at bottom of the units and metering device.

  • @mj24672
    @mj24672 2 дні тому

    A couple weeks ago, when I turned my central air on, it wasn’t cooling. I had forgotten to take the cover off the unit. Now I’m finding that it has stopped working. I changed the batteries and circuit breakers and they’re all good but unable to check the rest. Hard to do with no man around. 😂

  • @aaronrich4560
    @aaronrich4560 2 дні тому

    Does which wire goes to where matter for the igniter? I was trying to replace mine and cannot remember which one went to which side of the igniter.

  • @drdickqueso
    @drdickqueso 2 дні тому

    Compressor - pressure raiser Condenser - heat rejector Metering device - pressure dropper Evaporator - heat absorber

  • @mtbbiker6401
    @mtbbiker6401 2 дні тому

    I don't understand how taking a low pressure (vapor line) reading at the condenser translates to the pressure in the evaporator. Why is it not industry standard to take low pressure (vapor line) reading at the evaporator?

  • @Ray-wr2wr
    @Ray-wr2wr 2 дні тому

    Hi I have a MXZ-8C-60NA2 total 4 zones new set up 3 zones working fine as as I turn 4th zone my suction line goes down below 50psi or 10° 2-3 hours later error code 1501 , when I turn on heat mode my suction line goes to RETARD above 350psi I checked all communication wires all matching, planing on disconnecting high side on the branch box for that particular 4th zone see if my workers forgot to remove cup from the branch box flaring part 🤔 There is 1x MXZ-8C-60NA2 also 4 zones doing amazing job I have total 2x MXZ-8C-60NA2 8 zones at this particular job site in Queens ny. Any advice would be appreciated!!! I watched most of your content good info!!!, thank you for putting all the effort 🙏

  • @MarkSlusher-d1r
    @MarkSlusher-d1r 2 дні тому

    Thanks! Just saved me a whole lot of money.

  • @me2speed316
    @me2speed316 2 дні тому

    Probably a stupid question, but if I've already figured out that the blower motor is the problem, how do i know if the motor is an 825 or 1075 rpm model? I can't find anything to match part numbers to the rheem website from the information panel on the main ac into.

  • @electrolatif
    @electrolatif 2 дні тому

    The best aircon video in UA-cam ❤

  • @justinhughes452
    @justinhughes452 2 дні тому

    What was the recommended amount of refrigerant on the name plate? How much was in system at the start and what was the total amount at the rnd of this demonstration?

  • @bossume6966
    @bossume6966 2 дні тому

    Adapters for absolutely no reason literally

  • @Bill_CBR
    @Bill_CBR 2 дні тому

    I've never seen an HVAC technician attach a temperature sensor to the equipment at my home.

  • @samkitty5894
    @samkitty5894 2 дні тому

    Another reason, if it was made in China. It will fail soon, when you least expect it.

  • @Ahmed198831
    @Ahmed198831 2 дні тому

    🙏🙏🙏🙏

  • @gingerstrand6153
    @gingerstrand6153 2 дні тому

    Great video, thank you!!

  • @Bob-cx4ze
    @Bob-cx4ze 2 дні тому

    What about the 24v thermostat wires?

  • @chadhartsees
    @chadhartsees 2 дні тому

    So basically it's making sure that all the refrigerant is boiled off into a low pressure vapor state by time it reaches the end of it's time in the evaporator. "Give me more, I can boil more" or "Hold on, I'm boiling all I can." in a constant dynamic flux.

  • @edwardlouie
    @edwardlouie 2 дні тому

    This method doesn't always work with inverter variable speed equipment that change the superheat target based on various logics.

  • @edwardlouie
    @edwardlouie 2 дні тому

    I like using core depressors so I don't need to spin on/off quickly.